SHV-1,3-“Laminar-S.” (530.130)

 
Fume hood 530.130
Fume hood 
 SHV-1,3-“Laminar-S.”
 
Air flow scheme of fume hood
Air flow scheme
 

SHV-1,3-“Laminar-S.” is designed for use in laboratories providing operator’s protection when working with chemically harmful materials and for their effective removal from the operating area.

Application of the Fume Hoods 

  • removes chemically harmful and low-toxic materials from the working zone providing operator’s protection in laboratories with different profiles; 
  • Fume hoods are designed to be used as part of the external exhaust system in clinical, diagnostic, dental, and other laboratories, medical organizations, food production and other industries.  
  • Fume hoods are used for studies and works causing and spreading toxic vapors and gases harmful to human health and for work with materials that require quick elimination of accessory substances from the operating area. 
  • Fume hoods are not to be used with hazardous and potentially hazardous pathogenic agents and microorganisms

Main Features of the Fume Hood SHV-1,3-“Laminar-S.” (530.130)

Work Chamber

  • Front sash is hinged, made of tempered glass; opening/closing mechanism is gas springs;
  • Metal side walls;
  • Luminance of the work chamber;
  • Sockets unit inside the work chamber;
  • Stainless steel tabletop

 UV-unit

  • Pull-out UV unit located under the tabletop.

Air Exhaust Elements 

  • Auxiliary blower;
  • Back-flow valve with connecting flange to the exhaust system Ø 250 mm;
  • Goffered metal hose Ø 250 mm, length 3 meters;
  • 2 quick-release pipe bridges for metal hose attachment.

Control System Elements

  • Highlighted key switch for switching on/off the power to the cabinet, for switching on/off the lighting, for switching on/off the fan.
  • UV control unit is equipped with anti-vandal buttons and timer with display with seven segments. 

Support

  • Frame stand with foot rest;
  • Screw supports are available for stationary positioning of the cabinet at the exploitation sight

Main Parameters and Dimensions of the SHV-1,3-“Laminar-S.” (530.130):

Dimensions of the assembled cabinet with stand, mm (WхDхH) 1315х600х1920
Dimensions of the work chamber, mm (WхDхH) 1310х535х675
Mass of assembled cabinet with the stand, kg, not more than 98
Input power of the cabinet, W, not more than (exclusively of the load on the built-in outlets) 95
Input power of the fan, W, not more than 31
Maximum load allowed on the sockets, W 1000
Luminance level in the working zone, lux, not less than 1000*
Airflow outflow volume, m3/hr, not less than  500

* - integral value defined on the total surface of the work zone. 

Additional Options

  • Gas tap without electromagnetic valve
  • Vacuum tap without electromagnetic valve
  • Additional set of sockets (installed on the left side)
  • Stainless steel sink 165х288х120 together with drain valve and mixer tap (0.05.1) (installed on the left side)
  • Stainless steel sink 165х288х120 together with drain valve and mixer tap (0.05.1) (installed on the right side)
  • Mixer tap for water supply (hot/cold)
  • Tap for water supply (brass) (model 11080.1)
  • Cabinet base with an air vent (together with the fume hood)/(in a separate package)
  • Tabletop “Polystone”

Dimensional drawing of SHV-1,3-“Laminar-S.” (530.130)

 

Dimensional drawing of SHV-1,3-“Laminar-S.” (530.130)